Set to head

This commit is contained in:
InsanityAutomation
2019-09-19 21:06:06 -04:00
parent 7d6c4bfa5e
commit 16fd59f130
282 changed files with 2211 additions and 1840 deletions
@@ -971,12 +971,11 @@
/**
* Z Probe to nozzle (X,Y) offset, relative to (0, 0).
* Default X and Y offsets must be integers.
* Floats may be set with M851 if required.
*
* In the following example the X and Y offsets are both positive:
* X and Y offsets must be integers.
*
* #define NOZZLE_TO_PROBE_OFFSET { 10, 10, 0 }
* In the following example the X and Y offsets are both positive:
* #define X_PROBE_OFFSET_FROM_EXTRUDER 10
* #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
*
* +-- BACK ---+
* | |
@@ -988,10 +987,10 @@
* | |
* O-- FRONT --+
* (0,0)
*
* Specify a Probe position as { X, Y, Z }
*/
#define NOZZLE_TO_PROBE_OFFSET { -22, 0, -1.5 }
#define X_PROBE_OFFSET_FROM_EXTRUDER -22 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 0 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -1.5 // Z offset: -below +above [the nozzle]
#define MIN_PROBE_EDGE 10
// X and Y axis travel speed (mm/m) between probes
@@ -1023,7 +1022,7 @@
*
* Use these settings to specify the distance (mm) to raise the probe (or
* lower the bed). The values set here apply over and above any (negative)
* probe Z Offset set with NOZZLE_TO_PROBE_OFFSET, M851, or the LCD.
* probe Z Offset set with Z_PROBE_OFFSET_FROM_EXTRUDER, M851, or the LCD.
* Only integer values >= 1 are valid here.
*
* Example: `M851 Z-5` with a CLEARANCE of 4 => 9mm from bed to nozzle.
@@ -1375,7 +1375,7 @@
#define MIN_STEPS_PER_SEGMENT 6
/**
* Minimum delay after setting the stepper DIR (in ns)
* Minimum delay before and after setting the stepper DIR (in ns)
* 0 : No delay (Expect at least 10µS since one Stepper ISR must transpire)
* 20 : Minimum for TMC2xxx drivers
* 200 : Minimum for A4988 drivers
@@ -1387,7 +1387,8 @@
*
* Override the default value based on the driver type set in Configuration.h.
*/
//#define MINIMUM_STEPPER_DIR_DELAY 650
//#define MINIMUM_STEPPER_POST_DIR_DELAY 650
//#define MINIMUM_STEPPER_PRE_DIR_DELAY 650
/**
* Minimum stepper driver pulse width (in µs)
@@ -917,12 +917,11 @@
/**
* Z Probe to nozzle (X,Y) offset, relative to (0, 0).
* Default X and Y offsets must be integers.
* Floats may be set with M851 if required.
*
* In the following example the X and Y offsets are both positive:
* X and Y offsets must be integers.
*
* #define NOZZLE_TO_PROBE_OFFSET { 10, 10, 0 }
* In the following example the X and Y offsets are both positive:
* #define X_PROBE_OFFSET_FROM_EXTRUDER 10
* #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
*
* +-- BACK ---+
* | |
@@ -934,10 +933,10 @@
* | |
* O-- FRONT --+
* (0,0)
*
* Specify a Probe position as { X, Y, Z }
*/
#define NOZZLE_TO_PROBE_OFFSET { -3, 31, -1.25 }
#define X_PROBE_OFFSET_FROM_EXTRUDER -3 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 31 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -1.25 // Z offset: -below +above [the nozzle]
// Certain types of probes need to stay away from edges
#define MIN_PROBE_EDGE 0
@@ -971,7 +970,7 @@
*
* Use these settings to specify the distance (mm) to raise the probe (or
* lower the bed). The values set here apply over and above any (negative)
* probe Z Offset set with NOZZLE_TO_PROBE_OFFSET, M851, or the LCD.
* probe Z Offset set with Z_PROBE_OFFSET_FROM_EXTRUDER, M851, or the LCD.
* Only integer values >= 1 are valid here.
*
* Example: `M851 Z-5` with a CLEARANCE of 4 => 9mm from bed to nozzle.
@@ -1377,7 +1377,7 @@
#define MIN_STEPS_PER_SEGMENT 6
/**
* Minimum delay after setting the stepper DIR (in ns)
* Minimum delay before and after setting the stepper DIR (in ns)
* 0 : No delay (Expect at least 10µS since one Stepper ISR must transpire)
* 20 : Minimum for TMC2xxx drivers
* 200 : Minimum for A4988 drivers
@@ -1389,7 +1389,8 @@
*
* Override the default value based on the driver type set in Configuration.h.
*/
//#define MINIMUM_STEPPER_DIR_DELAY 650
//#define MINIMUM_STEPPER_POST_DIR_DELAY 650
//#define MINIMUM_STEPPER_PRE_DIR_DELAY 650
/**
* Minimum stepper driver pulse width (in µs)
@@ -904,12 +904,11 @@
/**
* Z Probe to nozzle (X,Y) offset, relative to (0, 0).
* Default X and Y offsets must be integers.
* Floats may be set with M851 if required.
*
* In the following example the X and Y offsets are both positive:
* X and Y offsets must be integers.
*
* #define NOZZLE_TO_PROBE_OFFSET { 10, 10, 0 }
* In the following example the X and Y offsets are both positive:
* #define X_PROBE_OFFSET_FROM_EXTRUDER 10
* #define Y_PROBE_OFFSET_FROM_EXTRUDER 10
*
* +-- BACK ---+
* | |
@@ -921,10 +920,10 @@
* | |
* O-- FRONT --+
* (0,0)
*
* Specify a Probe position as { X, Y, Z }
*/
#define NOZZLE_TO_PROBE_OFFSET { -3, 31, -1.25 }
#define X_PROBE_OFFSET_FROM_EXTRUDER -3 // X offset: -left +right [of the nozzle]
#define Y_PROBE_OFFSET_FROM_EXTRUDER 31 // Y offset: -front +behind [the nozzle]
#define Z_PROBE_OFFSET_FROM_EXTRUDER -1.25 // Z offset: -below +above [the nozzle]
// Certain types of probes need to stay away from edges
#define MIN_PROBE_EDGE 0
@@ -958,7 +957,7 @@
*
* Use these settings to specify the distance (mm) to raise the probe (or
* lower the bed). The values set here apply over and above any (negative)
* probe Z Offset set with NOZZLE_TO_PROBE_OFFSET, M851, or the LCD.
* probe Z Offset set with Z_PROBE_OFFSET_FROM_EXTRUDER, M851, or the LCD.
* Only integer values >= 1 are valid here.
*
* Example: `M851 Z-5` with a CLEARANCE of 4 => 9mm from bed to nozzle.
@@ -1377,7 +1377,7 @@
#define MIN_STEPS_PER_SEGMENT 6
/**
* Minimum delay after setting the stepper DIR (in ns)
* Minimum delay before and after setting the stepper DIR (in ns)
* 0 : No delay (Expect at least 10µS since one Stepper ISR must transpire)
* 20 : Minimum for TMC2xxx drivers
* 200 : Minimum for A4988 drivers
@@ -1389,7 +1389,8 @@
*
* Override the default value based on the driver type set in Configuration.h.
*/
//#define MINIMUM_STEPPER_DIR_DELAY 650
//#define MINIMUM_STEPPER_POST_DIR_DELAY 650
//#define MINIMUM_STEPPER_PRE_DIR_DELAY 650
/**
* Minimum stepper driver pulse width (in µs)