@@ -76,7 +76,7 @@
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
/**
* Whenever an M104, M109, or M303 increases the target temperature, the
@@ -100,11 +100,11 @@
#if ENABLED(THERMAL_PROTECTION_BED)
#if ENABLED(TREX3) && DISABLED(BedAC)
#define THERMAL_PROTECTION_BED_PERIOD 50 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#else
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#endif
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // Degrees Celsius
/**