Update Configuration_adv.h

This commit is contained in:
InsanityAutomation
2020-07-23 11:47:55 -04:00
committed by InsanityAutomation
parent 18d0e1b365
commit c86c85437f
+5 -5
View File
@@ -162,8 +162,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 15 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 70 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define ADAPTIVE_FAN_SLOWING // Slow part cooling fan if temperature drops
#if BOTH(ADAPTIVE_FAN_SLOWING, PIDTEMP)
@@ -182,7 +182,7 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 30 // Seconds
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#endif
@@ -190,7 +190,7 @@
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_PERIOD 30 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
/**
@@ -205,7 +205,7 @@
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 5 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
/**
* Heated chamber watch settings (M141/M191).